CHEMISTRY MACHINE
Model:
URIT 880
Country:
CHINA
Item details
URIT-880 Semi-automatic Chemistry Analyzer
- Display: 7-inch color touch screen (800 × 480 resolution)
- Memory: Stores up to 30,000 results
Optical System
- Light Source: Halogen lamp (90°–100° illumination angle)
- Wavelengths: 350nm, 450nm, 510nm, 550nm, 575nm, 645nm, 700nm *(8 wavelengths total; duplicates removed)*
- Filters: High-quality filters for dual-wavelength detection
- Absorbance Range: -0.34% – 4.04%
- Accuracy Bias: <5ms
- -Half Bandwidth: <10nm *(interpreted from "Half broadband")*
- -Cuvette (Flexwell): Quartz cell, 10mm optical diameter, 25μL volume
Sampling & Calibration
- Sampling Volume: Adjustable (10–9990 µL); recommended 3600 µL
- Carry-over Rate: <1.9%
- Drift Rate: <0.025kx/20mm
- Calibration: Individual wavelength calibration available
- Temperature Control
- Incubation Positions: 8 inner positions with temperature options:
- 25°C, 35°C, 37°C, or room temperature
- -Ambient Conditions: 10°C–35°C; humidity 40%–85%
Analysis Methods
- Endpoint, 2-point, inserts, and polygon methods *(corrected "Emplaint" to "Endpoint")*
- User Features
- Auto-Cleaning: Prompted after each test
- Maintenance: Easy-to-change external tubing; user-friendly interface
- Data Management: Supports external keyboards (PS2/USB), USB backups, and SDI PL-45 upgrades
URIT-880 Semi-automatic Chemistry Analyzer
- Display: 7-inch color touch screen (800 × 480 resolution)
- Memory: Stores up to 30,000 results
Optical System
- Light Source: Halogen lamp (90°–100° illumination angle)
- Wavelengths: 350nm, 450nm, 510nm, 550nm, 575nm, 645nm, 700nm *(8 wavelengths total; duplicates removed)*
- Filters: High-quality filters for dual-wavelength detection
- Absorbance Range: -0.34% – 4.04%
- Accuracy Bias: <5ms
- -Half Bandwidth: <10nm *(interpreted from "Half broadband")*
- -Cuvette (Flexwell): Quartz cell, 10mm optical diameter, 25μL volume
Sampling & Calibration
- Sampling Volume: Adjustable (10–9990 µL); recommended 3600 µL
- Carry-over Rate: <1.9%
- Drift Rate: <0.025kx/20mm
- Calibration: Individual wavelength calibration available
- Temperature Control
- Incubation Positions: 8 inner positions with temperature options:
- 25°C, 35°C, 37°C, or room temperature
- -Ambient Conditions: 10°C–35°C; humidity 40%–85%
Analysis Methods
- Endpoint, 2-point, inserts, and polygon methods *(corrected "Emplaint" to "Endpoint")*
- User Features
- Auto-Cleaning: Prompted after each test
- Maintenance: Easy-to-change external tubing; user-friendly interface
- Data Management: Supports external keyboards (PS2/USB), USB backups, and SDI PL-45 upgrades